AF

Restricted airflow: the lint screen or vent is clogged, or the vent is crushed, kinked or has too many turns. The dryer keeps running.

Also shown as Check Vent

Try this first: Clean the lint screen, check that the vent from the dryer to the wall is not crushed or kinked and the outside vent hood is clear. If it continues, have the home’s vent run cleaned.

F4 E3

Restricted airflow: the lint screen or vent is clogged, or the vent may be crushed, kinked or have too many turns. The dryer keeps running.

Try this first: Clean the lint screen, check the vent run is not crushed or kinked and is free of lint, and check the outside vent hood. If it continues, have the vent system cleaned.

F3 E2

Moisture sensor issue: five loads in a row were dried without the moisture sensor registering data.

Try this first: Press Power to clear the code. Make sure the dryer is level, and avoid drying very small loads or single items on automatic cycles.

F3 E5

Moisture sensor issue: five loads in a row were dried without the moisture sensor registering data.

Try this first: Press Power to clear the code; if the problem persists, call me.

L2

Low or no line voltage: there may be a problem with the home power supply that keeps the heater from turning on. The dryer keeps running without heat.

Try this first: Check that neither of the two household circuit breakers for the dryer is tripped. Touch any pad to clear the code.

Electric dryers.

F4 E4

Low or no line voltage: there may be a problem with the home power supply that keeps the heater from turning on.

Try this first: Check that neither of the two household circuit breakers for the dryer is tripped. Touch any pad to clear the code.

Electric dryers.

F4 E1

Heater system: there may be a problem with the heater or heater relays.

Try this first: Reset power by turning off the circuit breaker or unplugging the unit for one minute, then restoring power. If the code returns, call me.

F7 E1

Motor system: there may be a problem with the motor, control or associated wiring.

Try this first: Reset power by turning off the circuit breaker or unplugging the unit for one minute, then restoring power. If the code returns, call me.

F6 E1

Communication error: there may be a problem with the main control board, the user interface (touchpad) or the wiring between them.

Try this first: Reset power by turning off the circuit breaker or unplugging the unit for one minute, then restoring power. If the code returns, call me.

F1 E4

There may be an issue with the control unit or its wiring.

Try this first: Reset power by turning off the circuit breaker or unplugging the unit for 5 minutes, then restoring power. If the code returns, call me.

F2 E5

There may be an issue with the user interface (control panel) or its wiring.

Try this first: Reset power by turning off the circuit breaker or unplugging the unit for 5 minutes, then restoring power. If the code returns, call me.

F3 E1

Labeled ‘Exhaust Thermistor’: points to a problem with the exhaust temperature sensor circuit.

Try this first: Reset power by turning off the circuit breaker or unplugging the unit for one minute, then restoring power. If the code returns, call me.

The support page gives only the component name, not a full description.

F3 E3

Labeled ‘Inlet Thermistor’: points to a problem with the inlet temperature sensor circuit.

Try this first: Reset power by turning off the circuit breaker or unplugging the unit for one minute, then restoring power. If the code returns, call me.

The support page gives only the component name, not a full description.

PF

A power failure interrupted the drying cycle.

Try this first: Touch and hold Start to restart the cycle, or press Power to clear the display.

ERR

The door is not completely closed and latched; the dryer won’t run until it is.

Try this first: Push on the door to engage the latch. Some models have an upper and a lower latch, and both must be secure.

Loc

Not a fault: the control lock is on, so the dryer will not start.

Try this first: Press and hold the Control Lock key for 3 seconds to unlock.

When to call me

If the safe check doesn’t clear the code, or the same code keeps coming back, the dryer needs a real diagnosis. Error codes point to the system that failed, not always the exact part, so I test before I replace anything.

Never open panels, bypass a safety switch or work on gas or wiring yourself. Unplug the appliance or turn off its breaker if you smell burning or see water near electrical parts.

Upfront pricing

$65

Service call, waived when you approve the repair. You get an exact price before any work starts.

Stacked washer and dryer units have a $125 service call, also waived with the repair.

Where These Codes Come From

I checked every code on this page against Maytag’s own documentation on October 18, 2026, and left out any code I couldn’t confirm there. Meanings can differ between models and model years, so your owner’s manual or the tech sheet inside your dryer has the final word for your exact model.

FAQ

Maytag dryer code questions

What does error code AF mean on a Maytag dryer?

Restricted airflow: the lint screen or vent is clogged, or the vent is crushed, kinked or has too many turns. The dryer keeps running. Try this first: Clean the lint screen, check that the vent from the dryer to the wall is not crushed or kinked and the outside vent hood is clear. If it continues, have the home’s vent run cleaned. If the code comes back, call or text me at (480) 292-4746.

Restricted airflow: the lint screen or vent is clogged, or the vent may be crushed, kinked or have too many turns. The dryer keeps running. Try this first: Clean the lint screen, check the vent run is not crushed or kinked and is free of lint, and check the outside vent hood. If it continues, have the vent system cleaned. If the code comes back, call or text me at (480) 292-4746.

Moisture sensor issue: five loads in a row were dried without the moisture sensor registering data. Try this first: Press Power to clear the code. Make sure the dryer is level, and avoid drying very small loads or single items on automatic cycles. If the code comes back, call or text me at (480) 292-4746.

Moisture sensor issue: five loads in a row were dried without the moisture sensor registering data. Try this first: Press Power to clear the code; if the problem persists, call me. If the code comes back, call or text me at (480) 292-4746.

My service call is $65 ($125 for stacked washer and dryer units), and it’s waived when you approve the repair. I give you an exact price before any work starts.

Ready when you are

Code still showing? Book your dryer repair.

Call or text (480) 292-4746, Monday to Saturday, 9am to 6pm. Same-day and next-day appointments are often available.